Cornelius REMCOR R-134A Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Stroj na výrobu ledu Cornelius REMCOR R-134A. Cornelius REMCOR R-134A User's Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 54
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Installation/Service
Manual
IMPORTANT:
TO THE INSTALLER.
It is the responsibility of the Installer
to ensure that the water supply to the
dispensing equipment is provided
with protection against backflow by
an air gap as defined in ANSI/ASME
A112. 1.2-1979; or an approved
vacuum breaker or other such
method as proved effective by test.
Water pipe connections and fixtures
directly connected to a potable water
supply shall be sized, installed, and
maintained according to Federal,
State, and Local laws.
VENTURE POST--MIX DISPENSER
W/BUILT--IN COLD CARBONATOR
(R--134A REFRIGERANT)
PRINTED IN U.S.A
IMI CORNELIUS INC; 1995--99Ó
IMI CORNELIUS INC g One Cornelius Place g Anoka, MN 55303-6234
Telephone (800) 238-3600 Facsimile (612) 422-3246
Part No. 312027000
July 18, 1995
Revised: April 1, 1999
Control Code D
THIS DOCUMENT CONTAINS IMPORTANT INFORMATION
This Manual must be read and understood before installing or operating this equipment
Zobrazit stránku 0
1 2 3 4 5 6 ... 53 54

Shrnutí obsahu

Strany 1 - Installation/Service

Installation/ServiceManualIMPORTANT:TO THE INSTALLER.It is the responsibility of the Installerto ensure that the water supply to thedispensing equipme

Strany 2 - TABLE OF CONTENTS

5312027000THEORY OF OPERATION(see applicable Figure 2 or 3)WARNING: CO2displaces oxygen. Strict attention must be observed in the prevention ofCO2(car

Strany 3 - TABLE OF CONTENTS (cont’d)

6312027000SYRUP 1SYRUP 2SYRUP 3SYRUP 4SYRUP 5CARBONATEDWATER TANKCO2INLETCARBONATORPLAIN WATERINLETWATER PUMPDOUBLE LIQUIDCHECK VALVECO2CHECKVALVECARB

Strany 4

7312027000SYRUP 1SYRUP 2SYRUP 3SYRUP 4SYRUP 5CARBONATEDWATER TANKCO2INLETCARBONATORPLAIN WATERINLETWATER PUMPDOUBLE LIQUIDCHECK VALVECO2CHECKVALVECARB

Strany 5 - SAFETY INFORMATION

8312027000THIS PAGE LEFT BLANK INTENTIONALLY

Strany 6

9312027000INSTALLATIONThis section covers unpacking and inspection, selecting location, installing the Unit, preparing the Unit for op-eration, and Un

Strany 7

10312027000SELECTING LOCATIONCAUTION: This Unit is intended for indoor installation only. Do not install this Unit in anoutdoor environment which woul

Strany 8 - GENERAL INFORMATION

11312027000DISPENSING VALVEBLOCKDISPENSING VALVERELEASE LATCHSYRUP INLETTUBES (6)FIGURE 4. SYRUP INLET SUPPLY LINE CONNECTIONS (SIX-FLAVOR UNIT SHOWN)

Strany 9

12312027000IMPORTANT: TO THE INSTALLER. It is the responsibility of the Installer to ensure that the water supplyto the dispensing equipment is provid

Strany 10 - THEORY OF OPERATION

133120270001. Route syrup source lines from the syrup tanks location up to location under the countertop.2. Route syrup source lines up through hole c

Strany 11

143120270003. Install plug in water fill hole.4. 115 VAC, 60 HZUnits.Make sure the main power switch on right side of the Unit (see Figure 5) is in th

Strany 12

i 312027000TABLE OF CONTENTSPageSAFETY INFORMATION 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strany 13 - 312027000

153120270003. Open the plain water inlet supply line shutoff valve. Check for water leaks and tighten any looseconnections.4. Place the carbonator wat

Strany 14 - INSTALLATION

312027000 16THIS PAGE LEFT BLANK INTENTIONALLY

Strany 15 - INSTALLING UNIT

31202700017OPERATOR’S INSTRUCTIONSThis section covers operating controls, daily pre-operation check, Unit operation, adjustments, replenishingCO2and s

Strany 16

312027000 182. Make sure there is a sufficient syrup supply. If not, replenish the syrup supply as instructed in SERVICEAND MAINTENANCE section in thi

Strany 17

31202700019SANITIZING SYRUP SYSTEMSThe syrup systems should be sanitized as instructed every 90-days. Refer to SERVICE AND MAINTENANCEsection in this

Strany 18 - PREPARING UNIT FOR OPERATION

312027000 20THIS PAGE LEFT BLANK INTENTIONALLY

Strany 19 - UNIT OPERATION

31202700021SERVICE AND MAINTENANCEThis section describes service and maintenance procedures to be performed on the Unit.IMPORTANT: Only qualified pers

Strany 20

312027000 22HOOD RETAININGSCREW (1)CONDENSER FANMOTORCONDENSER COILWATER FILLHOLE PLUGDISPENSING VALVESKEYED-LOCK SWITCHDISPENSING VALVECOVER WITHWATE

Strany 21 - 312027000 16

31202700023NOTE: To readjust CO2regulator to a lower setting, loosen adjusting screw lock nut, then turn screw tothe left (counterclockwise) until pre

Strany 22 - OPERATOR’S INSTRUCTIONS

312027000 244. Install syrup separator on dispensing valve in place of the nozzle.5. Measure the water flow rate by dispensing water into a graduated

Strany 23 - DAILY CLEANING OF UNIT

ii312027000TABLE OF CONTENTS (cont’d)PageSANITIZING SYRUP SYSTEMS 19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .CHECKING

Strany 24 - SANITIZING SYRUP SYSTEMS

31202700025ADJUSTING WATER-TO-SYRUP “RATIO” (BRIX) OF DISPENSED PRODUCTSF-1 Dispensing Valve.(see Figure 6)NOTE: Make sure the dispensing valve water

Strany 25 - 312027000 20

312027000 265. Adjusting Syrup Flow Regulator -- If water and syrup levels are uneven in the ratio cup, adjust byturning the dispensing valve syrup fl

Strany 26 - SERVICE AND MAINTENANCE

31202700027CLEANING WATER TANK(see Figure 5 and 8)1. Unplug Unit power cord from electrical outlet.2. Shut off plain water supply to the Unit.3. Note

Strany 27

312027000 2824. Plug Unit power cord into electrical outlet.25. Dispense from one of the carbonated drink dispensing valves to bleed all air from the

Strany 28

312027000295. Remove nozzle and syrup diffusers from the dispensing valves. Place nozzles and syrup diffusers in sani-tizing solution.6. Wash the nozz

Strany 29

312027000 30Fill five-gallon container with potable water, then place all bag-in-box syrup containers syrup outlet tubes incontainer containing potabl

Strany 30

31202700031Place all bag-in-box syrup containers syrup outlet tubes in container containing potable water.20. Flush sanitizing solution from the syrup

Strany 31 - CHECKING ICE WATER BATH

312027000 32Servicing Water Pump Water Inlet Strainer Screen(see Figures 5 and 9)1. Unplug Unit power cord from electrical outlet.2. Remove the Unit h

Strany 32 - CLEANING WATER TANK

31202700033WATER LINE TO TANKDOUBLE-LIQUIDCHECK VALVEWHITE TAPERED GASKETELBOWPUMP TO MOTOR COUPLINGWATER PUMPWATERSTRAINER SCREEN(P/N 315348000)O-RIN

Strany 33 - CLEANING AND SANITIZING

312027000 3412341234ItemNo. Part No. Name1 5470E Flat Washer2 312418000 Ball Seat (Quad Ring)3 312419000 Ball4 5470D SpringFIGURE 10. LIQUID CHECK VAL

Strany 34

iii 312027000TABLE OF CONTENTS (cont’d)PageONLY SYRUP DISPENSED. 44. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .TROU

Strany 35 - 312027000 30

31202700035SYRUP TANK SYSTEM1. Disconnect empty syrup tank from syrup system.2. Check syrup drink quick disconnects for sticky or restricted operation

Strany 36 - SYSTEM DISRUPTIONS

312027000 36THE GERMAN ICE BANK CONTROL IS FORINTERNATIONAL USE ONLY.FIGURE 12. WIRING SCHEMATIC FOR ELECTRONIC ICE BANK CONTROL (OPTIONAL)

Strany 37 - 312027000 32

37312027000560001023FIGURE 13. WIRING DIAGRAM (50 AND 60 HZ UNIT WITH 1/3 H.P. REFRIGERATION ASSEMBLY)

Strany 38 - REPLENISHING CO

38312027000301112002FIGURE 14. WIRING DIAGRAM (60 HZ UNIT WITH 1/4 H.P. REFRIGERATION ASSEMBLY AND BUILT-IN COLD CARBONATOR)

Strany 39 - REPLENISHING SYRUP SUPPLY

39312027000301112002FIGURE 15. WIRING DIAGRAM (50 HZ UNIT WITH 1/4 H.P. REFRIGERATION ASSEMBLY AND BUILT-IN COLD CARBONATOR)

Strany 40 - GAS CHECK VALVES

312027000 40N.O.FRONTSOLENOIDTOP VIEWRIGHT SIDE VIEWSWITCHBLACKBLACKN.C.C21WHITEFIGURE 16. WIRING DIAGRAM (SF-1 DISPENSING VALVE)12CNOLEVERP/N 1925SWI

Strany 41 - INTERNATIONAL USE ONLY

41312027000THIS PAGE LEFT BLANK INTENTIONALLY

Strany 42 - 560001023

42312027000WARNING: If repairs are to be made to a product system, remove quick disconnects fromthe applicable product tank, then relieve the system p

Strany 43 - 301112002

43312027000Trouble Probable Cause RemedyADJUSTMENT OFDISPENSING VALVE SYRUPFLOW CONTROL DOES NOTDECREASE TO DESIREDWATER-TO-SYRUP “RATIO”.A. Dirty or

Strany 44

44312027000Trouble Probable Cause RemedyDISPENSED PRODUCTPRODUCES FOAM AS ITLEAVES DISPENSINGVALVE.(CONT’D)F. Dirty water supply. F. Check water filte

Strany 45

1 312027000SAFETY INFORMATIONRecognize Safety InformationThis is the safety-alert symbol. When you see thissymbol on our machine or in this manual, be

Strany 46

45312027000TROUBLESHOOTING REFRIGERATION SYSTEMTrouble Probable Cause RemedyCOMPRESSOR DOES NOTOPERATE.A. Ice bank sufficient. A. Refrigeration not ca

Strany 47

46312027000Trouble Probable Cause RemedyCOMPRESSOR OPERATESCONTINUOUSLY BUT DOESNOT FORM SUFFICIENT ICEBANK.A. Cooling capacity is exceededby over-dra

Strany 48

47312027000WARRANTYIMI Cornelius Inc. warrants that all equipment and parts are free from defects in material and workman-ship under normal use and se

Strany 50

IMI CORNELIUS INC.CORPORATE HEADQUARTERS:One Cornelius PlaceAnoka, Minnesota 55303-6234(612) 421-6120(800) 238-3600

Strany 52 - WARRANTY

2312027000THIS PAGE LEFT BLANK INTENTIONALLY

Strany 53

3312027000GENERAL INFORMATIONIMPORTANT: To the user of this manual - This manual is a guide for installing, operating, and main-taining this equipment

Strany 54 - (800) 238-3600

4312027000WARRANTY REFERENCE INFORMATIONWarranty Registration Date(to be filled out by customer)Unit Part Number:Serial Number:Install Date:Local Auth

Komentáře k této Příručce

Žádné komentáře