Strany 1 - Installation Manual

AURORAR10,000COOLING UNITInstallation ManualPRINTED IN U.S.AIMI CORNELIUS INC; 1988--93ÓPart No. 300381000July 13, 1988Revised: April 12, 1993THIS DOC

Strany 2 - TABLE OF CONTENTS

5 300381000INSTALLATIONThis section covers unpacking and inspection, selecting location, installing Cooling Unit, preparing for operation,and operatio

Strany 3 - TABLE OF CONTENTS (cont’d)

300381000 6fused as indicated on the Unit nameplate. The power circuit may also be wired through an equivalent HACRtype circuit breaker rather then th

Strany 4

7 300381000CONNECTING REMOTE CONDENSER COIL AND FAN ASS’Y (IF APPLICABLE)REFRIGERATION LINES TO COOLING UNIT(see Figure 6 )Connect refrigeration lines

Strany 5

300381000 8WARNING: The Cooling Unit must be electrically grounded to avoid possible fatal electricalshock or serious injury to the operator. A green

Strany 6 - GENERAL INFORMATION

9 300381000D. Reinstall Cooling Unit electrical control box and secure with four screws.E. Install cover on electrical handy box on back of Cooling Un

Strany 7

300381000 10CONNECTING COOLING UNIT SYRUP OUTLET LINES TO INSULATED PYTHON SYRUPLINES(see Figure 2)Connect Cooling Unit syrup outlet lines labeled No.

Strany 8 - SYSTEM THEORY OF OPERATION

11 3003810003. Lower Cooling Unit into operating position to complete seal from unit base to floor. Apply additional sealantaround bottom of base. Sea

Strany 9

300381000 12STARTING COOLING UNIT REFRIGERATION SYSTEMNOTE: As ice bank forms in water tank, water expansion will take place and excess water will esc

Strany 10 - INSTALLATION

13 300381000LEAK CHECK AND INSULATING COOLING UNIT OUTLET LINES1. Check all CO2, plain and carbonated water, and syrup connections for leaks and repai

Strany 11 - INSTALLING COOLING UNIT

300381000 14THIS PAGE LEFT BLANK INTENTIONALLY

Strany 12 - RESET BUTTON

i 300381000TABLE OF CONTENTSPageGENERAL INFORMATION 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strany 13 - 300381000 8

30038100015OPERATORS INSTRUCTIONSThis section covers operating controls, daily pre-operation check, adjustments, replenishing CO2and syrupsupplies, cl

Strany 14 - CONNECTING CO

300381000 16Cooling Unit Connected to Remote Condenser Coil and Fan Assembly.(see Figure 6)This Cooling Unit is equipped with a refrigeration system t

Strany 15

30038100017NOTE: When indicator on CO2cylinder regulator assembly 1800-psi gage is in shaded (‘ ‘change CO2cylinder’’) portion of the dial, CO2cylinde

Strany 16 - OPERATION

300381000 18COOLING UNIT CARBONATED WATER CIRCULATING PUMP MOTOR LUBRICATIONCarbonated water circulating pump motor bearings must be oiled periodicall

Strany 17 - ACTIVATING SYRUP SYSTEMS

19 300381000SERVICE AND MAINTENANCEThis section describes Service and Maintenance procedures to be performed on the Cooling Unit and theRemote Condens

Strany 18

300381000 20COOLING UNIT MAINTENANCEPERIODIC CLEANINGPeriodically wash all external surfaces of Cooling Unit, rinse with clean water, then wipe dry wi

Strany 19 - 300381000 14

21 3003810001. Disconnect electrical power from Cooling Unit at disconnect switch.2. Remove two screws securing Cooling Unit top cover, then remove co

Strany 20 - OPERATORS INSTRUCTIONS

300381000 22AIR FILTERRETAINING SCREW(4)ELECTRICALCONTROL BOXPLAIN WATERINLETFILTERBRACKETAIR FILTERCO2INLETCO2INLETCHECK VALVELIQUID DOUBLECHECK VALV

Strany 21 - ADJUSTMENTS

23 300381000REMOTE ROOFTOP CONDENSERCOIL AND FAN ASS’YREFRIGERATION LINES(ITEM 4 AND 5)TOP COVERTOP COVERRETAINING SCREW(2)HYDRO BOOSTRPLAIN WATER INL

Strany 22 - COOLING UNIT MAINTENANCE

300381000 24Servicing Carbonator Water Pump Water Strainer Screen. (see applicable Figure 5 or 6 and 8)1. Disconnect electrical power from Cooling Uni

Strany 23 - GAS CHECK VALVES

ii300381000TABLE OF CONTENTS (cont’d)PageADJUSTING DISPENSING VALVES WATER FLOW RATE 16. . . . . . . . . . . . .ADJUSTING WATER-TO-SYRUP ‘‘RATIO’’ OF

Strany 24 - SERVICE AND MAINTENANCE

25 3003810006. Reassemble check valves as shown in Figure 9. ALWAYS INSTALL NEW BALL SEAT (QUAD RING) P/N312418000.NOTE: Make sure when assembling che

Strany 25

300381000 26CARBONATED WATER CIRCULATING PUMP MOTOR LUBRICATION(see applicable Figure 5 or 6)Carbonated water circulating pump motor bearings must be

Strany 26 - CHANGING ICE WATER BATH

27 300381000IndexNo.PartNo.Name1 317963000 Housing2 312415000 Flat Washer, Stainless Steel3 *312418000 Ball Seat (quad ring)4 312419000 Ball5 31219600

Strany 27 - FAN ASSEMBLY)

300381000 28WATER FLOW RATERefer to Installation Instructions provided with dispensing station for dispensing valve water flow rate adjustmentinstruct

Strany 28 - 23 300381000

29 300381000SANITIZING POST-MIX SYRUP SYSTEMSIMPORTANT: Only qualified Service Personnel should perform sanitizing procedure on the post-mixsyrup syst

Strany 29 - 300381000 24

300381000 30C. Continue to activate the dispensing valve in cycles (“ON” for 15-seconds, “OFF”, then “ON” for15-seconds). Repeat “ON” and “OFF” cycles

Strany 30

31 30038100021. Repeat steps NO TAG and NO TAG preceding to purge sanitizing solution out of the remaining syrupsystems anddispensing valves.22. Remov

Strany 31

300381000 326. Open (counterclockwise) CO2cylinder valve slightly to allow lines to slowly fill with gas, then open valvefully to back-seat valve. (Ba

Strany 32 - REGULATORS

33 300381000FIGURE 11. REFRIGERATION FLOW DIAGRAM (STANDARD COOLING UNIT W/INTERNAL CONDENSERCOIL AND FAN ASS’Y)

Strany 33

300381000 34FIGURE 12. REFRIGERATION FLOW DIAGRAM (COOLING UNIT REQUIRING CONNECTION TOREMOTE CONDENSER COIL AND FAN ASS’Y)

Strany 34

iii 300381000TABLE OF CONTENTS (cont’d)PageTROUBLESHOOTING 39...WATER-TO-SYRUP ‘‘RATIO’’ OF DISPENS

Strany 35 - 300381000 30

3530038100030--9340--001REVISION BMODEL NUMBERS:416593496593FIGURE 13. WIRING DIAGRAM (LOW-VOLTAGE SYSTEM)

Strany 36 - REPLENISHING CO

363003810001054REVISION AMODEL NUMBER416594FIGURE 14. WIRING DIAGRAM (LOW-VOLTAGE SYSTEM)

Strany 37 - SYSTEM GAS CHECK VALVES

3730038100030--9356--000REVISION HMODEL NUMBERS:416593416594496593FIGURE 15. WIRING DIAGRAM (HIGH-VOLTAGE SYSTEM)

Strany 38 - COIL AND FAN ASS’Y)

38300381000THIS PAGE LEFT BLANK INTENTIONALLY

Strany 39 - 300381000 34

39 300381000WARNING: If repairs are to be made to a product system, remove quick disconnects fromthe applicable product tank, then relieve the system

Strany 40 - MODEL NUMBERS:

40300381000Trouble RemedyProbable CauseADJUSTMENT OFDISPENSING VALVE SYRUPFLOW REGULATOR DOESNOT DECREASE TODESIRED WATER-TO-SYRUP‘‘RATIO’’.A. Dirty o

Strany 41 - MODEL NUMBER

41 300381000Trouble RemedyProbable CauseONLY CARBONATED WATERDISPENSED (CONT’D)E. Dispensing valve syrup flowregulator, soft drink tank quickdisconnec

Strany 42 - REVISION H

42300381000Trouble RemedyProbable CauseE. Binding or damaged balancemechanism.E. Repair or replace balancemechanism.ERRATIC CYCLING OFCARBONATOR.A. Ba

Strany 43 - 38300381000

43 300381000Trouble RemedyProbable CauseCOMPRESSOR DOES NOTOPERATE (CONT’D)I. Hi-pressure cutout tripped(remote Cooling Unit only).I. Reset pressure s

Strany 44

44300381000Trouble RemedyProbable CauseCOMMPRESSOR OPERATESCONTINUOUSLS BUT DOESNOT FORM SUFFICIENT ICEBANK (CONT’D)E. Inoperative or disconnectedpuls

Strany 45

iv300381000TABLE OF CONTENTS (cont’d)PageLIST OF FIGURES CONT’D)FIGURE 14. WIRING DIAGRAM (LOW-VOLTAGE SYSTEM) 36. . . . . . . . . . . . . . . .FIGURE

Strany 46

45 300381000WARRANTYIMI Cornelius Inc. warrants that all equipment and parts are free from defects in material and workmanship un-der normal use and s

Strany 48

IMI CORNELIUS INC.CORPORATE HEADQUARTERS:One Cornelius PlaceAnoka, Minnesota 55303-6234(612) 421-6120(800) 238-3600

Strany 49

1300381000GENERAL INFORMATIONIMPORTANT: To the user of this manual - This manual is a guide for installing, operating, andmaintaining this equipment.

Strany 50 - WARRANTY

300381000 2Table 1. Design DataCOOLING UNIT MODEL NUMBERS:60 HZ Unit:Standard Cooling Unit with Internal Condenser Coil and Fan Assembly 416593Cooling

Strany 51

3300381000Table 1. Design Data (cont’d)REMOTE CONDENSER COIL AND FAN ASS’Y DATA (P/N 309602000)Overall Dimensions:Height 27 inchesWidth 22-inchesDepth

Strany 52 - (800) 238-3600

4300381000LINE LEGENDCO2PLAIN WATERCARB WATERSYRUPSHUTOFFVALVEWATER PRESSUREREGULATORWATER FILTERASS’YPLAIN WATERSOURCEPLAIN WATERSHUTOFF VALVESUGAR S

Komentáře k této Příručce

Žádné komentáře