Cornelius Ice Makers Training Manual
Publication Number: TP00967 - 12 - © 2003, IMI Cornelius Inc.
WCC/WCF CONTROLS AND ELECTRICAL
The WCC/WCF control circuit is a series circuit consisting of the following components:
1. Bin Control Electrical power is routed through the primary and the secondary bin controls. The
primary bin control is thermostatic, while the secondary is a mechanical switch located in the dis-
pense tray lid.
The purpose of the secondary switch is to act as a backup in the event of a primary switch failure. If
the ice backs up into the drop chute, the control is tripped by the ice accumulation and shuts down
the ice maker.
2. Low Water Safety Switch Opens the control circuit in the event of an interruption of the water
supply. Once water level is restored in the reservoir, operation will automatically resume.
3. High-Pressure Cutout Water-cooled units have a high-pressure cut-out in the event of failure of
the condenser to cool the refrigerant.
4. Anti-Freeze Relay This relay protects the contactor from voltage fluctuations that cause chatter
or contact point failure.
5. Manual Reset Overload A manual reset overload under the gearmotor stator shuts down the
entire ice maker should the maximum load of the gearmotor be exceeded.
6. Contactor Coil The contactor, once closed runs the refrigeration system and the gearmotor. The
ice maker, will continue to make ice without interruption until stopped by the opening of the bin con-
trol, or one of the above safety controls.