Cornelius Ice Makers Training Manual
Publication Number: TP00967 - 16 - © 2003, IMI Cornelius Inc.
IMD CONTROLS AND ELECTRICAL
The IMD series control circuit contains most of the same components used on the WCC/WCF units.
The following components are unique to certain IMD models.
Illuminated Merchandiser (Optional)
Key Switch (Optional)
Drink Front (Optional)
Auger Delay
Dispense Timer (Solid State Timer) P/N TE1-24X-31796
Stand-by Condition
Line voltage is present between black and white wires.
Timing Condition
Voltage is present between white and yellow only when the ice dispense switch is activated. When
accrued dispense time reaches 45 seconds the run condition occurs.
Run Condition
Line voltage is switched on at the red wire.
Full Bin Condition
0 voltage between black and white wires.
Test Procedure
System status - stand-by condition.
1. Connect the meters ground probe to the white wire.
2. With meter set to read 120 VAC, measure voltage between black and white voltage.
3. Measurement between white and red should be 0 VAC.
4. Measurement between white and yellow should be 0 VAC.
5. Depress the dispense switch and the white / yellow measurement should change from 0 VAC to line
voltage.
1
2
35
Blue
Red
Black
White
1
2
3
4
Yellow
Red
Black
White