630460146
16
October 27, 2003
SCALE 1:2
INNER WATER DISTRIBUTOR
INNER WATER DISTRIBUTOR BARB
”O” RING
”O” RING
WATER DIST. ASSEMBLY
FIG. 10
FIG. 11
5. Return the water curtain(s) to their proper operating positions.
6. Add 5 oz. for the 300’s, 8 oz. for the 500’s, 600’s, and 800’s, 12 oz. for the Dual Evaporator, and 16 oz. for
the Quad of “Calgon Nickel Safe” ice machine cleaner directly into the water pan (green only).
7. Turn the power switch to “ON” , allow the compressor to start, and depress the clean button two times on
the front of the electrical box.
8. The unit will run through a fifteen (15) minute cleaning cycle. This includes 3 rinse cycles.
9. Once the cleaning cycle finishes, the error LED will flash 6 times.
10. When the clean cycle is complete, turn the power switch to “OFF” for five (5) seconds, then to “ON”. The
unit will return to normal operating mode. Discard the first batch of ice produced.
NOTE: Please Take Note of the Following:
S Ice machines should only be cleaned when needed, not by a timed schedule of every 60 days, etc.
S Should your ice machine require cleaning more than twice a year, consult your distributor or dealer about
proper water treatment.
Sanitizing the Water System and the Evaporator
NOTE: To be performed only after cleaning the ice machine:
1. Turn the power switch to “OFF”.
2. Add 1/4 ounce (7.08 g) sodium hypochlorite solution (common liquid laundry bleach) to the water pan. You
may also use a commercial sanitizer such as Calgon Ice Machine Sanitizer following the directions on the
product label.
3. Turn the Cuber power switch “ON” allowing the compressor to start. Depress the clean button two times on
the control board. The unit will run through a 15 minute sanitizing cycle.
4. Once the sanitizing cycle is complete, the error LED will flash 6 times. Turn the power switch to “OFF” for
5 seconds and then turn to “ON”. Discard the first batch of ice produced.
5. To sanitize the bin and other surface areas, use 1 ounce of liquid bleach per gallon of water and wipe all
areas with the solution. Or use a commercial sanitizer.
6. Cleaning and sanitizing are now complete. Cuber may be returned to normal service.