UC100 Operator’s Manual
Publication Number: 621054211OPR - 6 - © 2008, IMI Cornelius Inc.
MAINTENANCE
WARNING: Disconnect Power Before Cleaning! Do not use metal scrapers, sharp objects,
or abrasives on the ice storage hopper, top cover, and agitator disk. Do not use solvents or
other cleaning agents because they may damage the plastic.
Soap solution
– Use a mixture of mild detergent and warm (100
o
F) potable water.
Sanitizing solution
– Dissolve one packet of Kay-5 Sanitizer/Cleaner into 2-1/2 gallons of water to ensure
100 ppm of available chlorine.
The following dispenser maintenance should be performed at the intervals indicated:.
DAILY (OR AS REQUIRED)
Remove foreign material from vending area drip tray to prevent drain blockage. Clean vending area.
Check for proper water drainage from the vending area drip tray.
Cleaning Exterior Surfaces
IMPORTANT: Perform the following daily.
1. Remove the cup rest from drip tray.
2. Wash the drip tray with soap solution. Rinse with potable water and allow solution to run down the
drain.
3. Wash cup rest with soap solution and rinse in potable water. Install the cup rest into the drip tray.
4. Clean all exterior surfaces with soap solution and rinse with potable water.
Ice Chute Maintenance
IMPORTANT: Perform the following daily.
NOTE: The ice chute has a built in safety
feature which disables the unit when the ice
chute cover is removed. If the ice chute
cover is not properly installed, the agitator
and ice chute gate will not function.
1. Grab the ice chute cover and slide it up
until it stops.
2. Pull the ice chute forward.
3. Remove the finger guard from the ice
chute cover by sliding the guard upward
then out.
4. Wash the ice chute, ice chute cover, finger
guard, and ice level flapper with a nylon
bristle brush and a clean rag using the
soap solution.
5. Rinse the parts with clean potable water
then rinse with sanitizing solution. Allow all
parts to air dry.
6. Replace the ice chute and slide down into
place.
7. If the agitator or ice chute are not working,
remove the ice chute cover and replace it.
8. Reinstall the finger guard onto the ice
chute cover.
Tower Cover
Auger Transition
Cap
Ice Chute
Finger
Guard
Ice Chute Cover
Komentáře k této Příručce