Cornelius Quantum 1000 Technické informace Strana 23

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 32
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 22
Wilshire Juice Training Manual
© 1999, IMI Cornelius Inc. - 17 -
TROUBLE SHOOTING
TROUBLESHOOTING QLT DRINK QUALITY PROBLEMS
ACTUAL PROBLEM & SYMPTOMS CUSTOMER REACTION
Concentrate too cold:
Low brix
False refill light
Poorly mixed drink
Unmixed concentrate at bottom of cup
Poor flow rate
Decrease water flow
Might correct brix
False refill light
Poorly mixed drink
Pulsing/splashing dispense
Unmixed concentrate at bottom of cup
NOTE: After 2-4 hours the concentrate
will match the cabinet temper-
ature becoming more viscous
resulting in high brix
Concentrate too warm
High brix
Increase water flow
NOTE: After 2-4 hours the concentrate
will match the cabinet temper-
ature becoming less viscous
resulting in low brix
Piercing device created a flap when it
pierced through the pouch
Low brix
False refill light
Decrease water flow
Might correct brix
False refill light
Poorly mixed drink
Pulsing/splashing dispense
Unmixed concentrate at bottom of cup
NOTE: Correct by rotating piercing
device 90-180°F
Warm Hydrometer
Floats higher in the cup indicating high
brix
Increase water flow
Might lower brix
Drinks taste weak
TROUBLE SHOOTING
Zobrazit stránku 22
1 2 ... 18 19 20 21 22 23 24 25 26 27 28 ... 31 32

Komentáře k této Příručce

Žádné komentáře