IDC 255 Progate Drive Thru Service Manual
© 2006, IMI Cornelius Inc. - 3 - Publication Number: 621057419SER
FIGURE 1
Electrical Connections: 6 ft long power cord with 3-prong plug attached to dispenser.
Power Requirements: 9.3 amps at 120 volts dedicated power supply.
Water Supply Requirements: 100 psi (7 bar) maximum static pressure 40 psi (28 bar) minimum
dynamic pressure. 3/8” minimum water line recommended.
CO2 Requirements: 100 psi max to unit regulated to 35 psi (2.4 bar) to Progate 2 ice gate system, 75
psi (5.2 bar) carbonator.
Progate 2 Features
Progate Portion Ice Control Features
• 4 Programmable ice dispense sizes
• Automatic/Manual Ice Dispense Modes
• Unit Power On/Off Switch
• Programmable Agitation Time
Lid Dispenser
• 4 lid dispenser locations on the unit
• 3 Separate removable lid dispensers for small/medium, large, and extra large lids
Straw Holder
• Holds up to 140 regular sleeved straws
LID DISPENSER MAINTENANCE
The lid dispensers are manufactured out of materials that can survive chlorine-based cleaners and warm
water <100°F. Ensure that the parts are thoroughly dried before refilling with lids.
NOTE: Lid dispenser parts should not be soaked in the powersoak washing machine as this will
result in the parts getting scratched. Instead the dispenser parts should be rinsed in warm soap
water and then dried.