IntelliCarb Drop-In Ice Cooled Installation Guide
© 2003-2005, IMI Cornelius Inc. - 11 - Publication Number: 630460204INS
Conversion Instructions for 1522 Valve #1 from Carb to Non/Carb
1. Remove the cup rest, front panel, and drip tray.
2. Remove insulation pad, 2 screws, and bracket (as shown above on page 10).
3. Pull out a plug fitting from the rear connection of the manifold.
4. Disconnect soda line from valve #1.
5. Assemble straight fitting and oetiker clamp to soda line from valve #1 (as shown on page 10).
6. Assemble soda line from valve #1 to manifold.
7. Assemble hose plug and clamp oetiker to soda line valve #1 (as shown on page 10).
8. Reassemble bracket, 2 screws, and insulation pad.
9. Reassemble drip tray, front panel, and cup rest.
Drop-In Installation
1. Install dispenser in counter following standard procedures.
2. Use the Template supplied to mark the location of the hole to be cut into the counter top. Cut the
hole as marked and remove the material.
3. Apply the double stick tape (if supplied with the loose shipped parts).
NOTE: To comply with the National Sanitation Foundation (NSF) requirements, the unit must be
sealed to the counter top.
4. Liberally apply a sealant, such as Dow Corning RTV 731 or equivalent, to the unit flange bottom sur-
face.
5. Lower the unit into position to complete the seal of the rim to the counter top. Apply additional seal-
ant around the rim to ensure a complete seal.
NOTE: Do not move the unit after positioning or the seal will be broken.
6. Remove any excess sealant.
NOTE: For non-electrical valves, skip the next step.
7. Mount the Transformer power supply under the counter, in a position to allow access to the electrical
outlet and to allow the 24V power cord to reach the dispenser.
8. Install the drain hose to the ice bin drain fitting and route the drain hose to a permanent drain.
9. Mount secondary CO
2
regulator, carbonator pump with motor, and valve transformer in a conve-
nient location, no more than 7 feet from the unit.
10. Connect carbonator motor 3 wire plug to the tower 3 wire harness.
Connect the tower 2 wire harness to the transformer.
Carbonator
motor and
pump
assembly
Valve
transformer
Secondary
regulator